The Role of Nursing in Reducing Laboratory Errors through Specimen Management: A Narrative Review
Abstract
Background: Laboratory diagnostics underpin up to 70% of clinical decisions, yet 40-70% of laboratory errors occur in the pre-analytical phase—a process largely controlled by nursing during specimen collection and handling. Preventable errors in identification, technique, and transport persist, causing patient harm and systemic inefficiency.
Aim: This review synthesizes evidence on nursing's pivotal role in specimen management, analyzes error root causes, and evaluates the effectiveness of nursing-led interventions aimed at improving laboratory safety and specimen quality.
Methods: A systematic literature search (2010-2025) was performed across PubMed, CINAHL, Scopus, and Web of Science using relevant keywords. The analysis focused on error epidemiology, causative factors, and intervention outcomes related to education, technology, and system redesign.
Results: Nursing practice is the decisive factor for pre-analytical quality. Primary errors stem from misidentification, incorrect tube use, poor technique causing hemolysis, and improper handling. Effective, multimodal interventions include sustained competency-based education, barcode patient identification systems, standardized kits, dedicated phlebotomy teams, and closed-loop quality feedback, collectively reducing errors by 50-80%.
Conclusion: Nurses are fundamental guardians of diagnostic integrity. Sustainable error reduction necessitates a systemic, non-punitive strategy integrating robust education, smart technology, standardized workflows, and a supportive culture. Empowering nursing in this domain is a critical lever for enhancing patient safety, diagnostic accuracy, and healthcare value.
Full text article
References
Ahmed, Y. A., Alamri, R., ALenezi, M. D., Alenezi, A. H., Al-enezi, M. H., Alenizi, O. F., & Alshehri, A. F. (2022). Increased patient satisfaction and safety by following implementation of an electronic specimen collection module in phlebotomy during COVID-19 pandemic.
Al Atiyyah, A. H., Al Mutairi, D. M., Al Johani, K. I., Al Mutairi, M. B., Al Abdaly, H. S., Albreak, I. A., ... & Alrasheedi, W. A. (2024). Laboratory-Nursing Partnerships in Managing Multi-Drug-Resistant Organisms (MDROs): A Comprehensive Review. Saudi Journal of Medicine and Public Health, 1(1), 154-164. https://doi.org/10.64483/jmph-73
AlSahly, S. N. S., Alothiqi, I. A. M., Alzahrani, N. A. S., Halawi, M. Y. M., Alharbi, Y. A. I., Hazazi, Y. A. A., ... & Garada, A. A. (2025). Evaluating Pre-analytical and Post-analytical Errors in Laboratory Processes and Their Impact on Diagnostic Delay and Patient Safety in Family Medicine Referrals. Vascular and Endovascular Review, 8(13s), 1-6.
Aljehani, M. R., & Alhayek, A. A. (2024). Renal function assessment: core responsibilities of clinical pathologists and laboratory technicians in diagnostic evaluation. Saudi Journal of Medicine and Public Health, 1(1), 65-74. https://doi.org/10.64483/jmph-39
Arslan, S., Kuzu Kurban, N., Takmak, Ş., Şanlialp Zeyrek, A., Öztik, S., & Şenol, H. (2022). Effectiveness of simulation‐based peripheral intravenous catheterization training for nursing students and hospital nurses: A systematic review and meta‐analysis. Journal of Clinical Nursing, 31(5-6), 483-496. https://doi.org/10.1111/jocn.15960
Carraro, P., & Plebani, M. (2007). Errors in a stat laboratory: types and frequencies 10 years later. Clinical chemistry, 53(7), 1338-1342. https://doi.org/10.1373/clinchem.2007.088344
Chawla, R., Goswami, B., Singh, B., Chawla, A., Gupta, V. K., & Mallika, V. (2010). Evaluating laboratory performance with quality indicators. Laboratory Medicine, 41(5), 297-300. https://doi.org/10.1309/LMS2CBXBA6Y0OWMG
Cherie, N., Berta, D. M., Tamir, M., Yiheyis, Z., Angelo, A. A., Mekuanint Tarekegn, A., ... & Teketelew, B. B. (2024). Improving laboratory turnaround times in clinical settings: A systematic review of the impact of lean methodology application. PloS one, 19(10), e0312033. https://doi.org/10.1371/journal.pone.0312033
Cornes, M. (2020). The preanalytical phase–Past, present and future. Annals of Clinical Biochemistry, 57(1), 4-6. https://doi.org/10.1177/0004563219867989
Da Rin, G. (2010). Pre-Analytical Workstations as a Tool for Reducing Laboratory Errors. Journal of Medical Biochemistry, 29(4). DOI: 10.2478/v10011-010-0031-x
Delianu, C., Hurjui, L. L., Tărniceriu, C. C., Blaj, M., Tamaș, C., Toma, V., ... & Foia, L. (2021). Medical Staff Training-Quality Initiative to Reduce Errors in the Pre-Preanalytical Phase. Clinical Laboratory, (1). Doi: 10.7754/Clin.Lab.2020.200346
Getawa, S., Aynalem, M., Melku, M., & Adane, T. (2023). Blood specimen rejection rate in clinical laboratory: A systematic review and meta-analysis. Practical laboratory medicine, 33, e00303. https://doi.org/10.1016/j.plabm.2022.e00303
Gupta, S., Kapil, S., & Sharma, M. (2018). Improvement of laboratory turnaround time using lean methodology. International journal of health care quality assurance, 31(4), 295-308. https://doi.org/10.1108/IJHCQA-08-2016-0116
Lippi, G., Mattiuzzi, C., & Favaloro, E. J. (2015). Pre-analytical variability and quality of diagnostic testing. Looking at the moon and gazing beyond the finger. New Zealand Journal of Medical Laboratory Science, 69(1), 4-8. https://search.informit.org/doi/10.3316/informit.150223144699339
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., ... & Simundic, A. M. (2011). Preanalytical quality improvement: from dream to reality. Clinical Chemistry & Laboratory Medicine, 49(7). Doi 10.1515/CCLM.2011.600
Lippi, G., Betsou, F., Cadamuro, J., Cornes, M., Fleischhacker, M., Fruekilde, P., ... & Working Group for Preanalytical Phase (WG-PRE), European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). (2019). Preanalytical challenges–time for solutions. Clinical Chemistry and Laboratory Medicine (CCLM), 57(7), 974-981. https://doi.org/10.1515/cclm-2018-1334
Lippi, G., & Plebani, M. (2020). Integrated diagnostics: the future of laboratory medicine?. Biochemia medica, 30(1), 18-30. https://hrcak.srce.hr/234032
Magnette, A., Chatelain, M., Chatelain, B., Ten Cate, H., & Mullier, F. (2016). Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories. Thrombosis journal, 14(1), 49. https://doi.org/10.1186/s12959-016-0123-z
Mahto, M., Kumar, V., Banerjee, A., Kumar, S., & Kumar, A. (2024). Pre-analytical errors in coagulation testing: a case series. Diagnosis, 11(1), 114-119. https://doi.org/10.1515/dx-2023-0110
McCaughey, E. J., Vecellio, E., Lake, R., Li, L., Burnett, L., Chesher, D., ... & Georgiou, A. (2016). Current methods of haemolysis detection and reporting as a source of risk to patient safety: a narrative review. The Clinical Biochemist Reviews, 37(4), 143. https://pubmed.ncbi.nlm.nih.gov/28167844/
Meier, F. A., Badrick, T. C., & Sikaris, K. A. (2018). What’s to be done about laboratory quality? Process indicators, laboratory stewardship, the outcomes problem, risk assessment, and economic value: responding to contemporary global challenges. American Journal of Clinical Pathology, 149(3), 186-196. https://doi.org/10.1093/ajcp/aqx135
Morias, C., Palmer, G., & Santhakumar, A. (2023). Pre-analytical errors and their prevention in an emergency department setting. Australian Journal of Medical Science, 44(2), 46-61. https://search.informit.org/doi/10.3316/informit.378126164960094
Nordin, N., Ab Rahim, S. N., Omar, W. F. A. W., Zulkarnain, S., Sinha, S., Kumar, S., & Haque, M. (2024). Preanalytical errors in clinical laboratory testing at a glance: source and control measures. Cureus, 16(3). DOI: 10.7759/cureus.57243
Plebani, M. (2010). The detection and prevention of errors in laboratory medicine. Annals of clinical biochemistry, 47(2), 101-110. https://doi.org/10.1258/acb.2009.009222
Rahim, S. N., Nordin, N., Zulkeflee, H. A., Nik, W. N., Shuaib, W. M., Ismail, T. S., & Shafii, N. (2025). The Pre-Analytical Aspects of Blood Gas Analysis Point-Of-Care-Testing (POCT) and Their Impact on Clinical Decision-Making. Clinical Laboratory, 71(5). Doi: 10.7754/Clin.Lab.2024.241029
Ruiz, J. S., Frota, O. P., & Ferreira, M. A. (2024). Knowledge, Attitudes, and Practices of nurses regarding blood culture collection. Revista Brasileira de Enfermagem, 77(6), e20230424. https://doi.org/10.1590/0034-7167-2023-0424
Saathoff, A. M., MacDonald, R., & Krenzischek, E. (2018). Effectiveness of specimen collection technology in the reduction of collection turnaround time and mislabeled specimens in emergency, medical-surgical, critical care, and maternal child health departments. CIN: Computers, Informatics, Nursing, 36(3), 133-139. DOI: 10.1097/CIN.0000000000000402
Santos, P. R., Silva, C. L., Gall, M. C., & Grando, A. C. (2021). Impact of pre-analytical errors on costs of clinical analysis laboratory. Jornal Brasileiro de Patologia e Medicina Laboratorial, 57, e2872021. https://doi.org/10.5935/1676-2444.20210023
Simundic, A. M., & Lippi, G. (2012). Preanalytical phase–a continuous challenge for laboratory professionals. Biochemia medica, 22(2), 145-149. https://hrcak.srce.hr/83218
Valenstein, P. N., & Sirota, R. L. (2004). Identification errors in pathology and laboratory medicine. Clinics in laboratory medicine, 24(4), 979-96. https://doi.org/10.1016/j.cll.2004.05.013
Volmar, K. E., Idowu, M. O., Hunt, J. L., Souers, R. J., Meier, F. A., & Nakhleh, R. E. (2014). Surgical pathology report defects: a College of American Pathologists Q-Probes study of 73 institutions. Archives of Pathology and Laboratory Medicine, 138(5), 602-612. https://doi.org/10.5858/arpa.2013-0099-CP
World Health Organization, & Center for Disease Control. (2010). Basic malaria microscopy. World Health Organization.
Authors
Copyright (c) 2025 Mizinha Aied Alharbi, Amani Nadheem Aldhefeeri, Nouf Turki Lafi Alhomaidani, Amani Obaid Mathan Alruwaili, Mona Atua Soud Alshammri, Dlaiel Thany ALdhafeeri, Ghazal Abdulrahman Surayyi Alotaibi, Fetim Sultan Al Harbi, Fatimah Eid Alshammri, Hana Fehid Sagheer Aldhafeeri, Ghazal Abdulrahman Surayyi Alotaibi

This work is licensed under a Creative Commons Attribution 4.0 International License.